level measurement

News

Contact US

SHENZHEN HYKING INDUSTRIAL CO., LTD.
Address:Rm513, Scientific Building,Tsinghua Information Port,Nanshan Dist., Shenzhen
TEL:86-755-83285022 400 066 1913
Fax:86-755-83285033
E-mail:export@hyking.com
Conductive Point level detection Liquipoint FTW33

Conductive Point level detection Liquipoint FTW33

Product number:EH202511211611316647
Product description:Very compact flush-mounted probe for liquid and pasty media
Purchase price:$0.00 Original price:$0.00

Product Description

Field of application

The Liquipoint FTW33 is developed for the food industry and meets all international hygiene requirements. The device also fits perfectly for applications in all industries. For use in pasty and sticky media and media with heavy build-up.

For use in pipes and in storage, mixing and process vessels with or without an agitator. For liquids with electrical conductivity >1 μS/cm or dielectric constant >2. Developed for the food industry. Detection of foam occurring within the food industry possible.

  • Process connections: Threads and hygiene connections

  • Sensor length: Flush-mounted

  • Temperature: -20 to +100°C (-4 to +212°F), CIP/SIP to 150°C (302°F) for 1 hour

  • Pressure: 0 to 25bar abs (0 to 362,5psi abs)

  • Hygienic certificates

Benefits

  • Perfect fit to the hygienic industry thanks to flush-mounted design, which allows pigging of pipes

  • Safe and reliable measurement due to build-up compensation, ensuring reliable switching; IO-Link reduces costs and complexity due to easy configuration and flexible integration in all fieldbus systems

  • Individual adjustment to each medium not necessary

  • Easy installation thanks to compact design, even in tight conditions or where access is restricted

  • Broad range of process connections for installation in new and existing plants

  • CIP and SIP cleanability ensured - up to protection class IP 69

  • LED display for on-site function check

Specs at a glance

  • Process temperature

    Standard:
    -20 ... 100°C
    Cleaning:
    -20 ... 150°C for 1h
    ( -4 ... 302°F for 1h)

  • Process pressure / max. overpressure limit

    Vacuum ... 25 bar
    (Vacuum ... 362,5 psi)


Online service
  • Telephone(WeChat):19879185591
    点击这里给我发消息